Artigo em Inglês | MEDLINE | ID: mdl-35982943

RESUMO

Purpose: Deep brain stimulation is a neurosurgical procedure used in treatment of a growing spectrum of movement disorders. Inaccuracies in electrode placement, however, can result in poor symptom control or adverse effects and confound variability in clinical outcomes. A deformable 3D-2D registration method is presented for high-precision 3D guidance of neuroelectrodes. Methods: The approach employs a model-based, deformable algorithm for 3D-2D image registration. Variations in lead design are captured in a parametric 3D model based on a B-spline curve. The registration is solved through iterative optimization of 16 degrees-of-freedom that maximize image similarity between the 2 acquired radiographs and simulated forward projections of the neuroelectrode model. The approach was evaluated in phantom models with respect to pertinent imaging parameters, including view selection and imaging dose. Results: The results demonstrate an accuracy of (0.2 ± 0.2) mm in 3D localization of individual electrodes. The solution was observed to be robust to changes in pertinent imaging parameters, which demonstrate accurate localization with ≥20° view separation and at 1/10th the dose of a standard fluoroscopy frame. Conclusions: The presented approach provides the means for guiding neuroelectrode placement from 2 low-dose radiographic images in a manner that accommodates potential deformations at the target anatomical site. Future work will focus on improving runtime though learning-based initialization, application in reducing reconstruction metal artifacts for 3D verification of placement, and extensive evaluation in clinical data from an IRB study underway.

2.
Artigo em Inglês | MEDLINE | ID: mdl-36090307

RESUMO

Purpose: A method and prototype for a fluoroscopically-guided surgical robot is reported for assisting pelvic fracture fixation. The approach extends the compatibility of existing guidance methods with C-arms that are in mainstream use (without prior geometric calibration) using an online calibration of the C-arm geometry automated via registration to patient anatomy. We report the first preclinical studies of this method in cadaver for evaluation of geometric accuracy. Methods: The robot is placed over the patient within the imaging field-of-view and radiographs are acquired as the robot rotates an attached instrument. The radiographs are then used to perform an online geometric calibration via 3D-2D image registration, which solves for the intrinsic and extrinsic parameters of the C-arm imaging system with respect to the patient. The solved projective geometry is then be used to register the robot to the patient and drive the robot to planned trajectories. This method is applied to a robotic system consisting of a drill guide instrument for guidewire placement and evaluated in experiments using a cadaver specimen. Results: Robotic drill guide alignment to trajectories defined in the cadaver pelvis were accurate within 2 mm and 1° (on average) using the calibration-free approach. Conformance of trajectories within bone corridors was confirmed in cadaver by extrapolating the aligned drill guide trajectory into the cadaver pelvis. Conclusion: This study demonstrates the accuracy of image-guided robotic positioning without prior calibration of the C-arm gantry, facilitating the use of surgical robots with simpler imaging devices that cannot establish or maintain an offline calibration. Future work includes testing of the system in a clinical setting with trained orthopaedic surgeons and residents.

3.
Med Image Anal ; 68: 101917, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33341493

RESUMO

PURPOSES: Surgical reduction of pelvic fracture is a challenging procedure, and accurate restoration of natural morphology is essential to obtaining positive functional outcome. The procedure often requires extensive preoperative planning, long fluoroscopic exposure time, and trial-and-error to achieve accurate reduction. We report a multi-body registration framework for reduction planning using preoperative CT and intraoperative guidance using routine 2D fluoroscopy that could help address such challenges. METHOD: The framework starts with semi-automatic segmentation of fractured bone fragments in preoperative CT using continuous max-flow. For reduction planning, a multi-to-one registration is performed to register bone fragments to an adaptive template that adjusts to patient-specific bone shapes and poses. The framework further registers bone fragments to intraoperative fluoroscopy to provide 2D fluoroscopy guidance and/or 3D navigation relative to the reduction plan. The framework was investigated in three studies: (1) a simulation study of 40 CT images simulating three fracture categories (unilateral two-body, unilateral three-body, and bilateral two-body); (2) a proof-of-concept cadaver study to mimic clinical scenario; and (3) a retrospective clinical study investigating feasibility in three cases of increasing severity and accuracy requirement. RESULTS: Segmentation of simulated pelvic fracture demonstrated Dice coefficient of 0.92±0.06. Reduction planning using the adaptive template achieved 2-3 mm and 2-3° error for the three fracture categories, significantly better than planning based on mirroring of contralateral anatomy. 3D-2D registration yielded ~2 mm and 0.5° accuracy, providing accurate guidance with respect to the preoperative reduction plan. The cadaver study and retrospective clinical study demonstrated comparable accuracy: ~0.90 Dice coefficient in segmentation, ~3 mm accuracy in reduction planning, and ~2 mm accuracy in 3D-2D registration. CONCLUSION: The registration framework demonstrated planning and guidance accuracy within clinical requirements in both simulation and clinical feasibility studies for a broad range of fracture-dislocation patterns. Using routinely acquired preoperative CT and intraoperative fluoroscopy, the framework could improve the accuracy of pelvic fracture reduction, reduce radiation dose, and could integrate well with common clinical workflow without the need for additional navigation systems.


Assuntos
Ortopedia , Cirurgia Assistida por Computador , Imagem Corporal , Fluoroscopia , Fixação de Fratura , Humanos , Imageamento Tridimensional , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Artigo em Inglês | MEDLINE | ID: mdl-32476703

RESUMO

Pelvic trauma surgical procedures rely heavily on guidance with 2D fluoroscopy views for navigation in complex bone corridors. This "fluoro-hunting" paradigm results in extended radiation exposure and possible suboptimal guidewire placement from limited visualization of the fractures site with overlapped anatomy in 2D fluoroscopy. A novel computer vision-based navigation system for freehand guidewire insertion is proposed. The navigation framework is compatible with the rapid workflow in trauma surgery and bridges the gap between intraoperative fluoroscopy and preoperative CT images. The system uses a drill-mounted camera to detect and track poses of simple multimodality (optical/radiographic) markers for registration of the drill axis to fluoroscopy and, in turn, to CT. Surgical navigation is achieved with real-time display of the drill axis position on fluoroscopy views and, optionally, in 3D on the preoperative CT. The camera was corrected for lens distortion effects and calibrated for 3D pose estimation. Custom marker jigs were constructed to calibrate the drill axis and tooltip with respect to the camera frame. A testing platform for evaluation of the navigation system was developed, including a robotic arm for precise, repeatable, placement of the drill. Experiments were conducted for hand-eye calibration between the drill-mounted camera and the robot using the Park and Martin solver. Experiments using checkerboard calibration demonstrated subpixel accuracy [-0.01 ± 0.23 px] for camera distortion correction. The drill axis was calibrated using a cylindrical model and demonstrated sub-mm accuracy [0.14 ± 0.70 mm] and sub-degree angular deviation.

5.
Phys Med Biol ; 65(16): 165012, 2020 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-32428891

RESUMO

Metal artifacts present a challenge to cone-beam CT (CBCT) image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy-often in the very region of interest pertinent to the imaging/surgical tasks. We present a method to reduce the influence of metal artifacts by prospectively defining an image acquisition protocol-viz., the C-arm source-detector orbit-that mitigates metal-induced biases in the projection data. The metal artifact avoidance (MAA) method is compatible with simple mobile C-arms, does not require exact prior information on the patient or metal implants, and is consistent with 3D filtered backprojection (FBP), more advanced (e.g. polyenergetic) model-based image reconstruction (MBIR), and metal artifact reduction (MAR) post-processing methods. The MAA method consists of: (i) coarse localization of metal objects in the field-of-view (FOV) via two or more low-dose scout projection views and segmentation (e.g. a simple U-Net) in coarse backprojection; (ii) model-based prediction of metal-induced x-ray spectral shift for all source-detector vertices accessible by the imaging system (e.g. gantry rotation and tilt angles); and (iii) identification of a circular or non-circular orbit that reduces the variation in spectral shift. The method was developed, tested, and evaluated in a series of studies presenting increasing levels of complexity and realism, including digital simulations, phantom experiment, and cadaver experiment in the context of image-guided spine surgery (pedicle screw implants). The MAA method accurately predicted tilted circular and non-circular orbits that reduced the magnitude of metal artifacts in CBCT reconstructions. Realistic distributions of metal instrumentation were successfully localized (0.71 median Dice coefficient) from 2-6 low-dose scout views even in complex anatomical scenes. The MAA-predicted tilted circular orbits reduced root-mean-square error (RMSE) in 3D image reconstructions by 46%-70% and 'blooming' artifacts (apparent width of the screw shaft) by 20-45%. Non-circular orbits defined by MAA achieved a further ∼46% reduction in RMSE compared to the best (tilted) circular orbit. The MAA method presents a practical means to predict C-arm orbits that minimize spectral bias from metal instrumentation. Resulting orbits-either simple tilted circular orbits or more complex non-circular orbits that can be executed with a motorized multi-axis C-arm-exhibited substantial reduction of metal artifacts in raw CBCT reconstructions by virtue of higher fidelity projection data, which are in turn compatible with subsequent MAR post-processing and/or polyenergetic MBIR to further reduce artifacts.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Metais/química , Imagens de Fantasmas , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Algoritmos , Artefatos , Humanos , Imageamento Tridimensional/métodos , Parafusos Pediculares , Coluna Vertebral/diagnóstico por imagem
6.
Phys Med Biol ; 65(13): 135009, 2020 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-32217833

RESUMO

Surgical reduction of pelvic dislocation is a challenging procedure with poor long-term prognosis if reduction does not accurately restore natural morphology. The procedure often requires long fluoroscopic exposure times and trial-and-error to achieve accurate reduction. We report a method to automatically compute the target pose of dislocated bones in preoperative CT and provide 3D guidance of reduction using routine 2D fluoroscopy. A pelvic statistical shape model (SSM) and a statistical pose model (SPM) were formed from an atlas of 40 pelvic CT images. Multi-body bone segmentation was achieved by mapping the SSM to a preoperative CT via an active shape model. The target reduction pose for the dislocated bone is estimated by fitting the poses of undislocated bones to the SPM. Intraoperatively, multiple bones are registered to fluoroscopy images via 3D-2D registration to obtain 3D pose estimates from 2D images. The method was examined in three studies: (1) a simulation study of 40 CT images simulating a range of dislocation patterns; (2) a pelvic phantom study with controlled dislocation of the left innominate bone; (3) a clinical case study investigating feasibility in images acquired during pelvic reduction surgery. Experiments investigated the accuracy of registration as a function of initialization error (capture range), image quality (radiation dose and image noise), and field of view (FOV) size. The simulation study achieved target pose estimation with translational error of median 2.3 mm (1.4 mm interquartile range, IQR) and rotational error of 2.1° (1.3° IQR). 3D-2D registration yielded 0.3 mm (0.2 mm IQR) in-plane and 0.3 mm (0.2 mm IQR) out-of-plane translational error, with in-plane capture range of ±50 mm and out-of-plane capture range of ±120 mm. The phantom study demonstrated 3D-2D target registration error of 2.5 mm (1.5 mm IQR), and the method was robust over a large dose range, down to 5 [Formula: see text]Gy/frame (an order of magnitude lower than the nominal fluoroscopic dose). The clinical feasibility study demonstrated accurate registration with both preoperative and intraoperative radiographs, yielding 3.1 mm (1.0 mm IQR) projection distance error with robust performance for FOV ranging from 340 × 340 mm2 to 170 × 170 mm2 (at the image plane). The method demonstrated accurate estimation of the target reduction pose in simulation, phantom, and a clinical feasibility study for a broad range of dislocation patterns, initialization error, dose levels, and FOV size. The system provides a novel means of guidance and assessment of pelvic reduction from routinely acquired preoperative CT and intraoperative fluoroscopy. The method has the potential to reduce radiation dose by minimizing trial-and-error and to improve outcomes by guiding more accurate reduction of joint dislocations.


Assuntos
Imageamento Tridimensional/métodos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Procedimentos Ortopédicos , Pelve/lesões , Pelve/cirurgia , Cirurgia Assistida por Computador , Algoritmos , Fluoroscopia , Humanos , Imagens de Fantasmas
7.
Artigo em Inglês | MEDLINE | ID: mdl-36082206

RESUMO

Purpose: We report the initial development of an image-based solution for robotic assistance of pelvic fracture fixation. The approach uses intraoperative radiographs, preoperative CT, and an end effector of known design to align the robot with target trajectories in CT. The method extends previous work to solve the robot-to-patient registration from a single radiographic view (without C-arm rotation) and addresses the workflow challenges associated with integrating robotic assistance in orthopaedic trauma surgery in a form that could be broadly applicable to isocentric or non-isocentric C-arms. Methods: The proposed method uses 3D-2D known-component registration to localize a robot end effector with respect to the patient by: (1) exploiting the extended size and complex features of pelvic anatomy to register the patient; and (2) capturing multiple end effector poses using precise robotic manipulation. These transformations, along with an offline hand-eye calibration of the end effector, are used to calculate target robot poses that align the end effector with planned trajectories in the patient CT. Geometric accuracy of the registrations was independently evaluated for the patient and the robot in phantom studies. Results: The resulting translational difference between the ground truth and patient registrations of a pelvis phantom using a single (AP) view was 1.3 mm, compared to 0.4 mm using dual (AP+Lat) views. Registration of the robot in air (i.e., no background anatomy) with five unique end effector poses achieved mean translational difference ~1.4 mm for K-wire placement in the pelvis, comparable to tracker-based margins of error (commonly ~2 mm). Conclusions: The proposed approach is feasible based on the accuracy of the patient and robot registrations and is a preliminary step in developing an image-guided robotic guidance system that more naturally fits the workflow of fluoroscopically guided orthopaedic trauma surgery. Future work will involve end-to-end development of the proposed guidance system and assessment of the system with delivery of K-wires in cadaver studies.